Table 26  Three-Phase Motor Specifications (60 Hz)
Type Motor
Model
Prefix
Rating Full Load Maximum
(S.F. Load)
Line to Line
Resistance
Ohms
Efficiency % Locked
Rotor
AMPS
KVA
Code
HP KW Volts Hz S.F. Amps Kilowatts Amps Kilowatts S.F. F.L.
8
Inch
239660 40 30 380 60 1.15 64 35 72 40 .16-.20 86 86 479 J
239600 40 30 460 60 1.15 53 35 60 40 .24-.30 86 86 396 J
239610 40 30 575 60 1.15 42 35 48 40 .39-.49 86 86 317 J
239661 50 37 380 60 1.15 79 43 88 49 .12-.16 87 87 656 K
239601 50 37 460 60 1.15 64 43 73 49 .18-.22 87 87 542 K
239611 50 37 575 60 1.15 51 43 59 49 .28-.34 87 87 434 K
239662 60 45 380 60 1.15 92 52 104 60 .09-.11 88 87 797 K
239602 60 45 460 60 1.15 76 52 86 60 .14-.17 88 87 658 K
239612 60 45 575 60 1.15 61 52 69 60 .22-.28 88 87 526 K
239663 75 55 380 60 1.15 114 64 130 73.5 .06-.09 88 88 1046 L
239603 75 55 460 60 1.15 94 64 107 73.5 .10-.13 88 88 864 L
239613 75 55 575 60 1.15 76 64 86 73.5 .16-.21 88 88 691 L
239664 100 75 380 60 1.15 153 85 172 97.5 .05-.06 89 89 1466 L
239604 100 75 460 60 1.15 126 85 142 97.5 .07-.09 89 89 1211 L
239614 100 75 575 60 1.15 101 85 114 97.5 .11-.13 89 89 969 L
239165 125 90 380 60 1.15 202 109 228 125 .03-.04 87 86 1596 K
239105 125 90 460 60 1.15 167 109 188 125 .05-.07 87 86 1318 K
239115 125 90 575 60 1.15 134 109 151 125 .08-.11 87 86 1054 K
239166 150 110 380 60 1.15 235 128 266 146 .02-.03 88 87 1961 K
239106 150 110 460 60 1.15 194 128 219 146 .04-.05 88 87 1620 K
239116 150 110 575 60 1.15 155 128 176 146 .06-.08 88 87 1296 K
239167 175 130 380 60 1.15 265 150 302 173 .02-.04 88 88 1991 J
239107 175 130 460 60 1.15 219 150 249 173 .04-.05 88 88 1645 J
239117 175 130 575 60 1.15 175 150 200 173 .06-.08 88 88 1316 J
239168 200 150 380 60 1.15 298 169 342 194 .02-.03 88 88 2270 J
239108 200 150 460 60 1.15 246 169 282 194 .03-.05 88 88 1875 J
239118 200 150 575 60 1.15 197 169 226 194 .05-.07 88 88 1500 J

Model numbers above are for three-lead motors. Six-lead motors with different model numbers have the same running performance, but when wye-connected for starting have locked rotor amps 33% of the values shown. Six-lead individual phase resistance=table X 1.5.
 
 
 
Pages 21-25 26 27 28 29 30 Pages 31-35
"Left click" to VIEW pdf. To SAVE pdf "Right Click" & choose
Page 25 | Page 27     
 
 
  Home     Corporate     Water Systems     Fueling Systems     International  
  TOP  

Copyright 1998-2007.  Please review our Terms of Use before accessing this site.
Franklin Electric Co., Inc.        400 E. Spring St.,  Bluffton,  IN,  46714,  U.S.A.
Contact Us              Tel: 260.824.2900           Fax: 260.824.2909